82 COVER STORY MILLER / march 2022 pressure is blown at a full 0.5 bar value at the beginning, then by the time, this value cannot be achieved in the normal time due to the ambient and working conditions, clogging of blower filters, humidity, and temperature. For this reason, the time is set longer than it should be. In this case, blowing cannot be done immediately after the pressure becomes 0.5 bar, air continues to be produced. However, this produced air is exhausted through a safety relief valve to keep the tank pressure constant at 0.5 bar. In this case, air that will never be used is produced with the highest power consumption and thrown out by a re- lief valve. Existing timer controllers are very primitive and are the biggest cause of inefficiency in existing systems. The blower energy consumption that will occur if these devices are used is given in Figure 4. Instead of these time-referenced devices, much more advanced devices with artificial intelligence tech- nology, such as Jetmaster, that can offer algorithms in which pressure and differential pressure combinations are used together, should be used. With these devices, blowing can be done as soon as the pressure reaches 0.5 bar. In this way, inefficiency is completely eliminated. In addition, the pressure can be set to the desired value according to the need. The blower energy consumption to be realized with artificial intelligence devices is given in Figure 4. Figure 4. Energy Consumption When Using Artificial Intelligence Device Figure 5. Energy Consumption and Cleaning Pres- sureWhen Using Normal Capacity Blower Figure 6. Energy Consumption and Cleaning Pres- sureWhen Using Higher Capacity Blower